Dimensions and electrical data

Cross Section 3×16+16
Phase Conductor
Number and cross section mm2 3×16
Insulation thickness mm 1.5
Pilot Conductor
Number and cross section mm2 1×16
Stranding mm 126/0,40
Conductor diameter Nom. mm 5.50
Insulation thickness mm 1.5
Cable details
Radial diameter of outer sheath mm 3.1
Min. overall diameter mm 30.9
Max. overall diameter mm 34.0
Min. bending radius mm 306
Max. pulling tension kgf 384
Appx. cable weight kg/km 2
Copper weight kg/km 1.1
Electrical details
“Continuous current | rating at 25°C Ambient” A 85
“Intermittent current | rating at 25°C Ambient” A 96
Max. DC resistance at 20°C
Phase Conductor Ω /km 1.24
Pilot Conductor Ω /km 1.24
4 screens in parallel connection Ω /km 1.05
Nom. reactance at 50Hz Ω /km 0.109
Nom. reactance at 60Hz Ω /km 0.131
Min. insulation | resistance at 20°C M Ω /km 435
3 phase voltage drop | on full load current mV/A/m 2.62

Manufactured by Üntel Kablo. Supplied and held in Singapore for delivery across ASEAN by Everwell Cables & Electrical (S.E.A.) Pte Ltd. Contact us for cross-section, drum length, certification and lead time.