Skip to product information
Üntel BS 6708 TYPE 7M

Üntel BS 6708 TYPE 7M

Ships within 3–5 business days, subject to prior ex-stock sales.

Technical support available

Custom lengths available on request

SS & IEC certified products

BS 6708 TYPE 7M — Üntel Kablo cable for mining applications.

Dimensions and electrical data

Cross Section 3×16+16+16 3×25+16+25 3×35+18+35 3×50+25+50 3×70+35+70 3×95+50+95 3×120+50+120 3×150+70+150
Phase Conductor
Number and cross section mm2 3×16 3×25 3×35 3×50 3×70 3×95 3×120 3×150
Insulation diameter Nom. mm 8.85 10.35 11.60 13.60 15.70 17.25 20.05 22.20
Screen diameter Nom. mm 11.15 12.65 13.90 15.90 18.00 19.55 22.35 24.50
Earth Conductor
Number and cross section mm2 1×16 1×16 1×18 1×25 1×35 1×50 1×50 1×70
Stranding mm 126/0,40 126/0,40 147/0,40 196/0,40 276/0,40 396/0,40 396/0,40 360/0,50
Conductor diameter Nom. mm 5.50 5.50 6.00 6.75 8.00 9.75 9.75 11.60
Pilot Conductor
Number and cross section mm2 1×16 1×25 1×35 1×50 1×70 1×95 1×120 1×150
Stranding mm 126/0,40 196/0,40 276/0,40 396/0,40 360/0,50 475/0,50 608/0,50 740/0,50
Conductor diameter Nom. mm 5.50 6.75 8.00 9.75 11.60 12.75 15.10 17.00
Insulation diameter Nom. mm 8.85 10.35 11.60 13.60 15.70 17.25 20.05 22.20
Screen diameter Nom. mm 11.15 12.65 13.90 15.90 18.00 19.55 22.35 24.50
Cable details
Min. overall diameter mm 35.8 39.7 43.1 48.5 55.1 62.4 68.0 70.4
Max. overall diameter mm 38.6 42.9 46.3 51.8 58.8 66.1 72.5 78.4
Min. bending radius mm 309 343 370 414 470 529 580 627
Max. pulling tension kgf 480 642 834 1.2 1.68 2 2 2
Appx. cable weight kg/km 2.5 3.15 3.65 4.7 6.35 8.2 9.9 11.8
Copper weight kg/km 1.13 1.38 1.8 2.45 3.35 4.5 5.3 7.35
Electrical details
“Continuous current | rating at 25°C Ambient” A 85 110 135 170 205 250 295 320
“Intermittent current | rating at 25°C Ambient” A 96 125 150 200 250 310 355 385
Max. DC resistance at 20°C
Phase Conductor Ω /km 1.24 0.795 0.565 0.393 0.277 0.21 0.164 0.132
Pilot Conductor Ω /km 1.24 0.795 0.565 0.393 0.277 0.21 0.164 0.132
4 screens and earth in parallel connection Ω /km 0.58 0.47 0.45 0.38 0.27 0.23 0.21 0.158
Nom. reactance at 50Hz Ω /km 0.109 0.107 0.101 0.098 0.095 0.094 0.092 0.08
Nom. reactance at 60Hz Ω /km 0.131 0.128 0.121 0.118 0.114 0.113 0.11 0.096
Min. insulation | resistance at 20°C M Ω /km 435 375 325 285 0.26 0.25 250 250
3 phase voltage drop on full load current mV/A/m 2.62 1.68 1.2 0.84 0.61 0.47 0.38 0.32

Manufactured by Üntel Kablo. Supplied and held in Singapore for delivery across ASEAN by Everwell Cables & Electrical (S.E.A.) Pte Ltd. Contact us for cross-section, drum length, certification and lead time.