Üntel KabloÜntel Kablo · Marine Cable
MGCH & MGCH - EMC
- Rated voltage
- 0.6/1 kV
- Standard
- DIN 89158 (IEC 600921353)
- Temperature range
- + 85°C
- Flame retardant
- IEC 60332 / 1 IEC 60332 / 3A
Type approvals and certificates
- Custom lengths cut to order
- Delivered across Southeast Asia
- Need help choosing? Call +65 6747 3336
About MGCH & MGCH - EMC
Cable Structure Conductor Stranded annealed copper wire IEC 60228 class 2 Insulation EPR compound Bedding Halogen-free bedding compound Screen Electrolytic plain copper braided screen (EMC) = %100 wrapped electrolytic copper tape Outer Sheath Halogen-free, flame retardant thermoplastic polyolefin-based compound (HM41SHF1) – HD 604 – IEC 332 I 3 Black or grey
Standards: EN 50268, HD 604, IEC 332, IEC 60092, IEC 60228, IEC 60332, IEC 60754, IEC 61034
Construction
- Conductor
- Stranded annealed copper wire IEC 60228 class 2
- Insulation
- EPR compound
- Outer sheath
- Halogen-free, flame retardant thermoplastic polyolefin-based compound (HM41SHF1) – HD 604 – IEC 332 I 3 Black or grey
Screen: Electrolytic plain copper braided screen (EMC) = %100 wrapped electrolytic copper tape
Bedding: Halogen-free bedding compound
Electrical and mechanical
- Rated voltage
- 0.6/1 kV
- Test voltage
- 3,5 kV
- Temperature range
- + 85°C
- Min bending radius
- 8*cable dia. (mm) fixed
Standards and compliance
- Standard
- DIN 89158 (IEC 600921353)
- Flame retardant
- IEC 60332 / 1 IEC 60332 / 3A
- Halogen / gas content
- IEC 60754 I 1 – 2
- Smoke density
- IEC 61034 I 1 – 2 (DIN EN 50268/1-2)
Application